SIEMENS Burner Control Unit LME 73.000A1
Jun 24, 2026
View Full Size
LME7… are used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation
The fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control.
The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4... or QRA10....
- Applications in accordance with EN 267: Gas burners for liquid fuels
- Applications in accordance with EN 676: Automatic forced draft burners for gaseous fuels
- Applications in accordance with EN 746-2: Industrial thermoprocessing equipment - Part 2: Safety requirements for combustion and fuel handling systems
- Type-tested and approved in accordance with DIN EN 298
RMG Turbine Meter, DN50, 6-100 m3/hr
Jun 15, 2026
View Full Size
TME 400 (Turbine Meter Electronic) type volumeters offer a number of advantages over classical mechanical turbine meters like display of actual flow rate, data and parameter archiving, various interfaces and optionally integrated volume correction.
Features
• Electronic totalizers
Main totalizer, additional start-stop or resettable totalizer for low flow (or slow down) cut-off by external signal.
• Low-torque metering system with long-term stability
Turbine design with a minimum of moving parts.
• Battery or mains operation
Autonomous operation with lithium cell for 6+ years or external power supply and backup battery to protect against power failures.
Autonomous operation with lithium cell for 6+ years or external power supply and backup battery to protect against power failures.
• Explosion protection
The TME 400 is intrinsically safe and can be used in zones 1 and 2.
The TME 400 is intrinsically safe and can be used in zones 1 and 2.
• Outputs Pulse outputs HF and LF (variable), alarm output, current output (4-20 mA, optional).
• Flow display
• Digital interface
serial RS 485 interface for Modbus connection.
• Storage of maximum value (Qm)
• Archive Integrated fail-safe parameter, event and measured value archive.
• RMGViewTME Provided software for convenient parameterization and management of device and stored data.


Upgrading Pressure Regulator with GECA 1-1/2" Gas Regulator, Pmax 20bar with Slam Shut Valve
Jun 15, 2026
View Full Size
GECA Direct Acting Pressure Regulator for Natural Gas Application.
The constancy of the regulated pressure and its accuracy, even with significant changes in the upstream pressure and/ or flow rate, make the REXI Series regulator especially suitable for power distribution networks in civil and industrial plants. The basic version of the REXI Series regulator is made according to European Standard EN 334, as a Fail to Open regulator.
The shut-off device can be calibrated for pressure increase, Over Pressure Shut-Off (OPSO) and/or for pressuredecrease, Under Pressure Shut-Off (UPSO). The two intervention modes can be calibrated independently by dedicated calibration springs: one spring for the maximum pressure intervention and the second spring for the minimum pressure intervention. REXI series can be supplied also without Slam Shut valve.
The REXI Series can be equipped with an incorporated relief valve that dischaREXIes the gas into the atmosphere when the regulator outlet pressure exceeds the set value. When the outlet pressure returns to below the set value, the relief valve closes again.
Ball Valve for Oxygen Application, DN150, ANSI 150
Jun 15, 2026
View Full Size
Our ball valve from POLIX, Slovenia installed and operating in plant for Oxygen gas application.
Antistatic & fire safe design
Welded construction
Body : Carbon Steel - A105, P235TR2
Ball : Stainless Steel - X5CrNi18-10 (A304)
Stem: Stainless Steel - X20Cr13 (A420)
Seats : PTFE
O- Ring : Viton
Handle : Carbon steel (Galvanized) - S235JR (RSt 37-2)
Working temperature: -20 °C/+60 °C
Weight : 129.50 kg