- ELECTRICAL PRODUCT
- FIXED GAS AND FLAME DETECTION SOLUTIONS
- GAS PRODUCT
- CONTRIVE BURNER CONTROL DEVICE
- DUNGS GAS COMPONENTS
- ACCESSORIES
- BALL VALVE
- BURNER MANAGEMENT SYSTEMS AUTOMATIC BURNER CONTROLS
- DOUBLE SOLENOID VALVES
- ELECTRO PNEUMATIC VALVES
- FILTER
- GASMULTIBLOC® MULTIFUNCTIONAL GAS CONTROLS
- MOTOR BUTTERFLY VALVES AND ACTUATORS
- PRESSURE REGULATORS
- PRESSURE SWITCHES FOR GAS AND AIR
- SOLENOID VALVES
- SYSTEM ENGINEERING GAS TRAINS - DUNGSHeatEngine
- VALVE PROVING SYSTEMS LINE LEAKAGE TESTERS-LABORATORY - KITCHEN
- View All
- ECLIPSE BURNER PARTS
- ECONEX GAS TRAIN PRODUCT
- ACCESSORIES FOR GEAR MOTORS
- AIR AND GAS BUTTERFLY VALVE
- DIAL PRESSURE GAUGE
- ELECTRIC ACTUATORS
- ENGINEERED GAS SKID & VALVE TRAIN - GAS PRESSURE REDUCTION STATION
- FLAME SUPERVISION - BURNER CONTROL
- FLAME SUPERVISION - UV DETECTION
- GAS BALL VALVE
- GAS FILTER SERIES (FE)
- GAS PRESSURE REGULATOR
- GAS PRESSURE SWITCH
- GAS SOLENOID & SHUT OFF VALVE
- LINEAR CONTROL VALVE SERIES (MPV)
- MODULATING CONTROL VALVE SERIES (MDV-B1..., B1... E)
- MODULATING CONTROL VALVE SERIES (MDV-D1)
- MOTORIZED BUTTERFLY VALVES ELECTRONIC OR PNEUMATIC ACTUATOR
- NEEDLE VALVE
- PACKAGED VALVE TRAINS - GAS SOLENOID & SHUT OFF VALVE
- SAFETY RELIEF VALVE
- SOLENOID BUTTERFLY VALVE SERIES (BFVS)
- TURBINE METER
- TWO-WAY MANUAL PRESSURE COCK WITH BLEED-OFF
- VALVE PROVING SYSTEM
- View All
- ENOLGAS BONOMI VALVE & ACTUATOR
- GAS BURNER COMTHERM UK
- AIR HEATER (AHP)
- AIR HEATER (HEF)
- AIR HEATER (HEM)
- AIR HEATER (HET)
- COMTHERM EK BURNER
- COMTHERM PROCESS CONE (PC) BURNER
- COMTHERM PROCESS PAK (PP) BURNER
- COMTHERM RECIRCULATION SIDE-PLATE (RSP) BURNER
- COMTHERM SIDE-PLATE (SP) BURNER
- COMTHERM TF IMMERSION BURNER
- COMTHERM TFR IMMERSION BURNER
- DIRECT FIRED AIR HEATER
- FUME INCINERATION BURNER
- PROCESS - HEAT NORMAL CAPACITY (PH)
- PROCESS - HEAT NORMAL CAPACITY (PHC)
- View All
- GAS BURNER SANTIN ITALY
- GAS BURNER SELAS USA
- GECA GAS TRAIN EQUIPMENT
- HONEYWELL
- MAXON BURNER PARTS
- MEDENUS GAS TRAIN PRODUCT
- MTI GAS DETECTOR
- POLIX VALVE
- SIEMENS BURNER PARTS
- YETEN COMBUSTION
- View All
- MECHANICAL PRODUCT
- PROCESS MEASUREMENT AND CONTROL
- THERMOPLASTIC SOLUTIONS
- STUEBBE AERATION & VENT VALVES
- STUEBBE BALL VALVES
- STUEBBE BUTTERFLY VALVES
- STUEBBE CHEMICAL PUMP
- STUEBBE DIAPHRAGM VALVES
- STUEBBE DISPLAY AND CONTROL UNIT
- STUEBBE LEVEL MEASUREMENT
- STUEBBE LIQUID FLOWMETERS
- STUEBBE PRESSURE REDUCING VALVES
- STUEBBE PRESSURE RELIEF VALVES
- STUEBBE PRESSURE SENSOR
- STUEBBE WATER JET PUMP
- View All
KS...A2-7: Klima-Set, Differential pressure switch for air
|
KS...A2-7: Klima-Set, Differential pressure switch for air |
Klima-Set Differential pressure switch for air
KS…A2-7
Technical description
Two separate pressure chambers with pressure-side connection to hose nipples.
Connection of ø 4 mm for each pressure chamber. Reference value (pressure difference) can be set directly.
Reference value can be read off externally through the transparent hood.
Precise function through special switching system in a frictionless bearing. Contact switchover is performed when the set reference value is exceeded or undershot. Complete mounting kit enclosed.
Application
The equipment is used in ventilation and air-conditioning systems, DDC. It is specially designed for monitoring air ducts, filters, drive units and blowers.
Approvals
EC type testing certificate as per:
• EC-Gas Appliances Regulation
Approvals in other important gasconsuming countries.
Functional description
Differential pressure switch in pressure and vacuum ranges. The differential pressure acts via the diaphragm against the force of the setting spring on the microswitch.
If the set reference value is exceeded or undershot, the circuit is switched on, off or over.
The differential pressure switch of the Klima-Set works without an auxiliary power.
DDC application
The switching contacts of the KlimaSet are made of gold-plated silver, for 24 V DC; 0.02 A.
When using the Klima-Set in conventional systems at 250 V AC, 4 A ohmic load, 2 A inductive load, cos ϕ 0.6, the gold-plated coating on the switching contacts burns off.
This makes a subsequent DDC application impossible.
KS…A2-7
Technical description
Two separate pressure chambers with pressure-side connection to hose nipples.
Connection of ø 4 mm for each pressure chamber. Reference value (pressure difference) can be set directly.
Reference value can be read off externally through the transparent hood.
Precise function through special switching system in a frictionless bearing. Contact switchover is performed when the set reference value is exceeded or undershot. Complete mounting kit enclosed.
Application
The equipment is used in ventilation and air-conditioning systems, DDC. It is specially designed for monitoring air ducts, filters, drive units and blowers.
Approvals
EC type testing certificate as per:
• EC-Gas Appliances Regulation
Approvals in other important gasconsuming countries.
Functional description
Differential pressure switch in pressure and vacuum ranges. The differential pressure acts via the diaphragm against the force of the setting spring on the microswitch.
If the set reference value is exceeded or undershot, the circuit is switched on, off or over.
The differential pressure switch of the Klima-Set works without an auxiliary power.
DDC application
The switching contacts of the KlimaSet are made of gold-plated silver, for 24 V DC; 0.02 A.
When using the Klima-Set in conventional systems at 250 V AC, 4 A ohmic load, 2 A inductive load, cos ϕ 0.6, the gold-plated coating on the switching contacts burns off.
This makes a subsequent DDC application impossible.