- ELECTRICAL PRODUCT
- FIXED GAS AND FLAME DETECTION SOLUTIONS
- GAS PRODUCT
- CONTRIVE BURNER CONTROL DEVICE
- DUNGS GAS COMPONENTS
- ACCESSORIES
- BALL VALVE
- BURNER MANAGEMENT SYSTEMS AUTOMATIC BURNER CONTROLS
- DOUBLE SOLENOID VALVES
- ELECTRO PNEUMATIC VALVES
- FILTER
- GASMULTIBLOC® MULTIFUNCTIONAL GAS CONTROLS
- MOTOR BUTTERFLY VALVES AND ACTUATORS
- PRESSURE REGULATORS
- PRESSURE SWITCHES FOR GAS AND AIR
- SOLENOID VALVES
- SYSTEM ENGINEERING GAS TRAINS - DUNGSHeatEngine
- VALVE PROVING SYSTEMS LINE LEAKAGE TESTERS-LABORATORY - KITCHEN
- View All
- ECLIPSE BURNER PARTS
- ECONEX GAS TRAIN PRODUCT
- ACCESSORIES FOR GEAR MOTORS
- AIR AND GAS BUTTERFLY VALVE
- DIAL PRESSURE GAUGE
- ELECTRIC ACTUATORS
- ENGINEERED GAS SKID & VALVE TRAIN - GAS PRESSURE REDUCTION STATION
- FLAME SUPERVISION - BURNER CONTROL
- FLAME SUPERVISION - UV DETECTION
- GAS BALL VALVE
- GAS FILTER SERIES (FE)
- GAS PRESSURE REGULATOR
- GAS PRESSURE SWITCH
- GAS SOLENOID & SHUT OFF VALVE
- LINEAR CONTROL VALVE SERIES (MPV)
- MODULATING CONTROL VALVE SERIES (MDV-B1..., B1... E)
- MODULATING CONTROL VALVE SERIES (MDV-D1)
- MOTORIZED BUTTERFLY VALVES ELECTRONIC OR PNEUMATIC ACTUATOR
- NEEDLE VALVE
- PACKAGED VALVE TRAINS - GAS SOLENOID & SHUT OFF VALVE
- SAFETY RELIEF VALVE
- SOLENOID BUTTERFLY VALVE SERIES (BFVS)
- TURBINE METER
- TWO-WAY MANUAL PRESSURE COCK WITH BLEED-OFF
- VALVE PROVING SYSTEM
- View All
- ENOLGAS BONOMI VALVE & ACTUATOR
- GAS BURNER COMTHERM UK
- AIR HEATER (AHP)
- AIR HEATER (HEF)
- AIR HEATER (HEM)
- AIR HEATER (HET)
- COMTHERM EK BURNER
- COMTHERM PROCESS CONE (PC) BURNER
- COMTHERM PROCESS PAK (PP) BURNER
- COMTHERM RECIRCULATION SIDE-PLATE (RSP) BURNER
- COMTHERM SIDE-PLATE (SP) BURNER
- COMTHERM TF IMMERSION BURNER
- COMTHERM TFR IMMERSION BURNER
- DIRECT FIRED AIR HEATER
- FUME INCINERATION BURNER
- PROCESS - HEAT NORMAL CAPACITY (PH)
- PROCESS - HEAT NORMAL CAPACITY (PHC)
- View All
- GAS BURNER SANTIN ITALY
- GAS BURNER SELAS USA
- GECA GAS TRAIN EQUIPMENT
- HONEYWELL
- MAXON BURNER PARTS
- MEDENUS GAS TRAIN PRODUCT
- MTI GAS DETECTOR
- POLIX VALVE
- SIEMENS BURNER PARTS
- YETEN COMBUSTION
- View All
- MECHANICAL PRODUCT
- PROCESS MEASUREMENT AND CONTROL
- THERMOPLASTIC SOLUTIONS
- STUEBBE AERATION & VENT VALVES
- STUEBBE BALL VALVES
- STUEBBE BUTTERFLY VALVES
- STUEBBE CHEMICAL PUMP
- STUEBBE DIAPHRAGM VALVES
- STUEBBE DISPLAY AND CONTROL UNIT
- STUEBBE LEVEL MEASUREMENT
- STUEBBE LIQUID FLOWMETERS
- STUEBBE PRESSURE REDUCING VALVES
- STUEBBE PRESSURE RELIEF VALVES
- STUEBBE PRESSURE SENSOR
- STUEBBE WATER JET PUMP
- View All
G...-A4 - Pressure Switch for gas and air /Field adjustable (USA/CDN)
|
G...-A4 - Pressure Switch for gas and air /Field adjustable (USA/CDN) |
Pressure Switch for gas and air
GAO-A4…
GMH-A4…
GML-A4…
Description
The GAO-, GMH- and GML-A4… ventless pressure switches are adjustable pressure switches for automatic burner controls.
These pressure switches are suitable for making and/or breaking a circuit when the medium pressure changes relative to the set point. The set point can be set in the field by an adjustable dial with an integrated scale. Test nipple integrated in metal housing to verify set point.
Application
The GAO-, GMH-, and GML-A4… pressure switch is recommended for industrial and commercial heating, ventilation and air-conditioning systems.
The GAO-, GMH-, and GML-A4… pressure switch is suitable for dry natural gas, propane, butane, air and other inert gases. Suitable for up to 0.1 % by volume, dry H2S.
A “dry” gas has a dew point lower than +15 °F and its relative humidity is less than 60 %.
GAO-A4… SPDT pressure switch requires no auxiliary power. The GAO-A4… is suitable for making and/or breaking a circuit when the set point is exceeded or undershot. A tripped switch is indicated by a neon light after set point is exceeded or undershot. Automatic reset when pressure returns below or above set point.
GMH-A4… SPDT pressure switch requires no auxiliary power. The GMH-A4… is suitable for making and/or breaking a circuit when the set point is exceeded. A tripped switch is indicated by a neon light after set point is exceeded. Manual reset is required to reset the switch.
GML-A4… SPDT pressure switch requires no auxiliary power. The GML-A4… is suitable for making and/or breaking a circuit when the set point is undershot. A tripped switch is indicated by a neon light after set point is undershot. Manual reset is required to reset the switch.
GAO-A4…
GMH-A4…
GML-A4…
Description
The GAO-, GMH- and GML-A4… ventless pressure switches are adjustable pressure switches for automatic burner controls.
These pressure switches are suitable for making and/or breaking a circuit when the medium pressure changes relative to the set point. The set point can be set in the field by an adjustable dial with an integrated scale. Test nipple integrated in metal housing to verify set point.
Application
The GAO-, GMH-, and GML-A4… pressure switch is recommended for industrial and commercial heating, ventilation and air-conditioning systems.
The GAO-, GMH-, and GML-A4… pressure switch is suitable for dry natural gas, propane, butane, air and other inert gases. Suitable for up to 0.1 % by volume, dry H2S.
A “dry” gas has a dew point lower than +15 °F and its relative humidity is less than 60 %.
GAO-A4… SPDT pressure switch requires no auxiliary power. The GAO-A4… is suitable for making and/or breaking a circuit when the set point is exceeded or undershot. A tripped switch is indicated by a neon light after set point is exceeded or undershot. Automatic reset when pressure returns below or above set point.
GMH-A4… SPDT pressure switch requires no auxiliary power. The GMH-A4… is suitable for making and/or breaking a circuit when the set point is exceeded. A tripped switch is indicated by a neon light after set point is exceeded. Manual reset is required to reset the switch.
GML-A4… SPDT pressure switch requires no auxiliary power. The GML-A4… is suitable for making and/or breaking a circuit when the set point is undershot. A tripped switch is indicated by a neon light after set point is undershot. Manual reset is required to reset the switch.
Download Files
- 226357.pdf (570.02 KB)