- ELECTRICAL PRODUCT
- FIXED GAS AND FLAME DETECTION SOLUTIONS
- GAS PRODUCT
- CONTRIVE BURNER CONTROL DEVICE
- DUNGS GAS COMPONENTS
- ACCESSORIES
- BALL VALVE
- BURNER MANAGEMENT SYSTEMS AUTOMATIC BURNER CONTROLS
- DOUBLE SOLENOID VALVES
- ELECTRO PNEUMATIC VALVES
- FILTER
- GASMULTIBLOC® MULTIFUNCTIONAL GAS CONTROLS
- MOTOR BUTTERFLY VALVES AND ACTUATORS
- PRESSURE REGULATORS
- PRESSURE SWITCHES FOR GAS AND AIR
- SOLENOID VALVES
- SYSTEM ENGINEERING GAS TRAINS - DUNGSHeatEngine
- VALVE PROVING SYSTEMS LINE LEAKAGE TESTERS-LABORATORY - KITCHEN
- View All
- ECLIPSE BURNER PARTS
- ECONEX GAS TRAIN PRODUCT
- ACCESSORIES FOR GEAR MOTORS
- AIR AND GAS BUTTERFLY VALVE
- DIAL PRESSURE GAUGE
- ELECTRIC ACTUATORS
- ENGINEERED GAS SKID & VALVE TRAIN - GAS PRESSURE REDUCTION STATION
- FLAME SUPERVISION - BURNER CONTROL
- FLAME SUPERVISION - UV DETECTION
- GAS BALL VALVE
- GAS FILTER SERIES (FE)
- GAS PRESSURE REGULATOR
- GAS PRESSURE SWITCH
- GAS SOLENOID & SHUT OFF VALVE
- LINEAR CONTROL VALVE SERIES (MPV)
- MODULATING CONTROL VALVE SERIES (MDV-B1..., B1... E)
- MODULATING CONTROL VALVE SERIES (MDV-D1)
- MOTORIZED BUTTERFLY VALVES ELECTRONIC OR PNEUMATIC ACTUATOR
- NEEDLE VALVE
- PACKAGED VALVE TRAINS - GAS SOLENOID & SHUT OFF VALVE
- SAFETY RELIEF VALVE
- SOLENOID BUTTERFLY VALVE SERIES (BFVS)
- TURBINE METER
- TWO-WAY MANUAL PRESSURE COCK WITH BLEED-OFF
- VALVE PROVING SYSTEM
- View All
- ENOLGAS BONOMI VALVE & ACTUATOR
- GAS BURNER COMTHERM UK
- AIR HEATER (AHP)
- AIR HEATER (HEF)
- AIR HEATER (HEM)
- AIR HEATER (HET)
- COMTHERM EK BURNER
- COMTHERM PROCESS CONE (PC) BURNER
- COMTHERM PROCESS PAK (PP) BURNER
- COMTHERM RECIRCULATION SIDE-PLATE (RSP) BURNER
- COMTHERM SIDE-PLATE (SP) BURNER
- COMTHERM TF IMMERSION BURNER
- COMTHERM TFR IMMERSION BURNER
- DIRECT FIRED AIR HEATER
- FUME INCINERATION BURNER
- PROCESS - HEAT NORMAL CAPACITY (PH)
- PROCESS - HEAT NORMAL CAPACITY (PHC)
- View All
- GAS BURNER SANTIN ITALY
- GAS BURNER SELAS USA
- GECA GAS TRAIN EQUIPMENT
- HONEYWELL
- MAXON BURNER PARTS
- MEDENUS GAS TRAIN PRODUCT
- MTI GAS DETECTOR
- POLIX VALVE
- SIEMENS BURNER PARTS
- YETEN COMBUSTION
- View All
- MECHANICAL PRODUCT
- PROCESS MEASUREMENT AND CONTROL
- THERMOPLASTIC SOLUTIONS
- STUEBBE AERATION & VENT VALVES
- STUEBBE BALL VALVES
- STUEBBE BUTTERFLY VALVES
- STUEBBE CHEMICAL PUMP
- STUEBBE DIAPHRAGM VALVES
- STUEBBE DISPLAY AND CONTROL UNIT
- STUEBBE LEVEL MEASUREMENT
- STUEBBE LIQUID FLOWMETERS
- STUEBBE PRESSURE REDUCING VALVES
- STUEBBE PRESSURE RELIEF VALVES
- STUEBBE PRESSURE SENSOR
- STUEBBE WATER JET PUMP
- View All
MEDENUS R51 GAS PRESSURE REGULATOR (DOSH AND ST APPROVED)
|
MEDENUS R51 GAS PRESSURE REGULATOR (DOSH AND ST APPROVED) |
MEDENUS R51
The MEDENUS gas pressure regulator type R51 ensures a constant outlet pressure - regardless of the primary (inlet) pressure - when the gas usage varies and ensures a quick pressure regulation when the flow rate abruptly changes. The gas pressure regulator R51 is best used for smaller flow rates or e.g. for ignition gas trains.
The gas pressure regulator R51 is suitable for gases in accordance with DVGW Code of Practice G260/262 and all other neutral and non-corrosive gases (others upon request).The gas pressure regulator R51 is available only with flange connections DN25, a maximum inlet pressure of 16 bar and a maximum outlet pressure of 3 bar. All gas pressure regulators are certified by DVGW and CE.
DESIGN AND FUNCTION
The spring-loaded gas pressure regulator R 51 has the function of keeping the outlet pressure of a gaseous medium constant within permissible liwith values, independently of the effect of interferences, such as changes in the inlet pressure and/ or in the gas flow, in the connected regulating line on the outlet side. The regulator is composed of the actuator housing and “diaphragm assembly plus actuator” functional unit.
The valve seat model is pre-pressure-compensated. The gas flows through the actuator housing in the direction of the arrow. The internal or external measurement line port is used for passing the outlet pressure to be regulated to the bottom of the diaphragm comparator of the diaphragm assembly. It compares the actual value with the command variable preset by the force of the setpoint spring. The setpoint required in each case is set via the setting screw. Any deviation from the setpoint is transwithted by the valve rod to the actuator, which is adjusted such that the actual value is adjusted to the setpoint.
In case of zero flow, the actuator will close tight, causing the closing pressure to be established.
PRODUCT DESCRIPTION
Sizes: | 1' |
Connections: | Flanged PN16 (ANSI on request) |
Materials: | |
Disk: | |
Joints & Seals: | |
Medium: | Gas |
Inlet Pressure (Max): | 10 Barg |
Outlet Pressure (Max): | 3 Barg |
Cv Range: | |
Temperature: | -20 to +60 degC |
Approvals: | |
Notes: | Single seated valve, Gas tight zero position. |
Product Videos
- MEDENUS R51 GAS PRESSURE REGULATOR
Download Files
- Datasheet_R51_en.pdf (864.63 KB)
- Operating_and_Maintenance_Instruction_R51_en.pdf (622.52 KB)
- Certificates_GGV-R51.pdf (734.23 KB)
- Certificates_DGR-R51.pdf (732.65 KB)