News & Events
STUEBBE PVDF Butterfly Valve DN125 PN10, FLM Seal
Sep 20, 2022
View Full Size
Advantage
• double shaft seal
• body with O-ring, no additional flange sealings required
Application
• chemical plants
• industrial plants
• electroplating plants
Intended Use
• for shutting off pipeline systems
Flow Media
• Neutral and aggressive fluid or gaseous media, provided that the valve components coming into contact with the media are resistant at the operating temperature in accordance with the ASV-resistance guide.
• Contaminated media may impair the sealing function.
Testing
• Requirements and tests/inspections according to DIN 3441, 3442, 8063 and 16962. DIN EN 12266, leakage rate A tested.
Contact us for more details!
Contact us for more details!
Honeywell Digital Burner Controller DBC2000, 230V
Sep 20, 2022
View Full Size
- Flame detection: UV sensor / Flame rod
- UV detectors: C7027A, C7035A, C7044A
- Pre-purge time: 35s
- Ignition time: 3s
- Flame failure response: 1s (max.)
HONEYWELL RM7890B1030 Automatic Primary Control 120VAC
Sep 20, 2022
View Full Size
Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls.
Features
- Functions include automatic burner sequencing, flame supervision, system status indication, system or self diagnostics and troubleshooting.
- Subbase and amplifier are required for operation.
- Options include PC interface, keyboard display module, DATA CONTROLBUS™ MODULE, remote display module, first-out expanded annunciator, and COMBUSTION SYSTEM MANAGER™ software.
- Five LEDs provide sequence information.
- Interchangeable plug-in flame amplifiers.
- Optional local or remote annunciation of operation and fault information.
- Nonvolatile memory retains history files and sequencing status after power loss.
- Optional remote reset capability.
- Optional report generation.
- Selectable relight or lockout on loss of flame.
HONEYWELL EC7895A1010 Automatic Programming Control 230VAC
Sep 20, 2022
View Full Size
Honeywell EC7895A1010 Primary Control. Microprocessor-based integrated primary burner control for automatically fired gas, oil, or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls.
• Functions include automatic burner sequencing, flame supervision, system status indication, system or self diagnostics and troubleshooting.
• Subbase, amplifier, and prepurge timer are required for operation.
• Options include PC interface, keyboard display module, DATA CONTROLBUS™ MODULE, remote display module, first-out expanded annunciator, and COMBUSTION SYSTEM MANAGER™ software.
• Five LEDs provide sequence information.
• Interchangeable plug-in flame amplifiers.
• Optional local or remote annunciation of operation and fault information.
• Nonvolatile memory retains history files and sequencing status after power loss.
• Optional remote reset capability.
• Optional report generation. Selectable relight or lockout on loss of flame.
• Airflow switch check.
• Functions include automatic burner sequencing, flame supervision, system status indication, system or self diagnostics and troubleshooting.
• Subbase, amplifier, and prepurge timer are required for operation.
• Options include PC interface, keyboard display module, DATA CONTROLBUS™ MODULE, remote display module, first-out expanded annunciator, and COMBUSTION SYSTEM MANAGER™ software.
• Five LEDs provide sequence information.
• Interchangeable plug-in flame amplifiers.
• Optional local or remote annunciation of operation and fault information.
• Nonvolatile memory retains history files and sequencing status after power loss.
• Optional remote reset capability.
• Optional report generation. Selectable relight or lockout on loss of flame.
• Airflow switch check.
HONEYWELL C7027A1049 Minipeeper UV Sensor, 1/2" Mounting,
Sep 20, 2022
View Full Size
Minipeeper Ultraviolet Flame Detector, Used for Coal, Gas and Oil Fired Burners, 96 Inch Lead Length, 0/215 Degree Ambient Temperature, Mounts on 1/2 Inch Sighting Pipe Using A Integral Collar, Includes 1/2 Inch NPT Spud Connector
MEDENUS Safety Shut Off Valve S100 DN150 PN16
Sep 16, 2022
View Full Size
- DN150 PN16
- Max. permissible pressure PS: 8 bar
- Building class: IS / Temperature: -20°C - +60°C
- Housing material: aluminum alloy
- Valve seat diameter: 125 mm
Do contact LSA for more details!
Medenus Gas Pressure Regulator RS250 with Safety Shut Off Valve DN50 PN16
Sep 16, 2022
View Full Size
- DN80, PN16
- Max. permissible pressure PS: 8 bar
- Building class: IS / Temperature: -20°C - +60°C
- Housing material: aluminum alloy
DUNGS Double Solenoid Valve 5080/632 eco with Proof of Closure
Aug 27, 2022
View Full Size
- DN80 PN16 Dual SSOV
- NBR 2POC CSA CE NEMA 12
- SPARE COIL 1511/2P248-503
DUNGS Double Solenoid Valve DMV 5100/11 eco Pmax 500mbar
Aug 27, 2022
View Full Size
- Two single stage solenoid valves, de-energised in absence of current, fast-opening, fast-closing.
- Connection: DN100
- Max operating pressure: 500 mbar
- Electrical rating: 50 - 60 Hz, 230 V AC
- Enclosure rating: IP54
DUNGS Differential Pressure Switch GGW 10 A4
Aug 26, 2022
View Full Size
Range 1-10 mbar
Pmax 500 mbar
Pmax 500 mbar